Welcome to Powerland Renewables!
Register for a Trade Account

Victron

11 products

  • Victron Energy Centaur Charger 12/20(3) – CCH012020000-Powerland

    Powerland Victron Energy Centaur Charger 12/20(3) – CCH012020000

    The Centaur range of battery chargers features auto-ranging input covering 90-265VAC 50/60Hz input meaning they can be used anywhere in the world. Crucially, and unlike many other products that state universal input, the Centaur range will maintain full output power within the entire specified range. Other features include fully automatic three stage charge characteristic that ensures batteries are fully charged every time and three isolated charge outputs for multi battery configurations to suit the majority of typical installations. The range spans 12V and 24V models from 16A through to 100A.   Features Quality without compromise Aluminium epoxy powder coated cases with drip shield and stainless steel fixings withstand the rigors of an adverse environment: heat, humidity and salt air. Circuit boards are protected with an acrylic coating for maximum corrosion resistance. Temperature sensors ensure that power components will always operate within specified limits, if needed by automatic reduction of output current under extreme environmental conditions.   Universal 90-265V AC input voltage range and also suitable for DC supply (AC-DC and DC-DC operation) All models will operate without any adjustment needed over a 90 to 265 Volt input voltage range, whether 50 Hz or 60 Hz. The chargers also accept a 90-400 V DC supply.   Three outputs that each can supply the full output current Three isolated outputs to simultaneously charge 3 battery banks. Each output is capable to supply the full rated current.   Three-stage charging, with temperature compensation The Centaur charges at bulk rate until the output has reduced to 70% of the rated Amps, at which a 4 hour timer begins. After the timed period the charger switches to float rate. An internal temperature sensor is used to compensate the charge voltage with – 2 mV/ºC (– 1 mV/ºF) per cell. A DIP switch is available to select the optimum charge/float voltages for Flooded Lead-acid, Gel or AGM batteries.   CLICK HERE FOR SPEC SHEET Brand Victron Energy Manufacturer Part Number CCH012020000 Voltage 12 Charger Amps 20 Outputs 3 Recommended Battery Capacity 80 – 200Ah Battery Connection M6 Studs IP Rating IP20 Dimensions H355 x W215 x D110mm Weight (kg) 3.8 Warranty 5 Years

    £258.60 Exc. VAT

    £310.32 Inc. VAT

  • Victron Energy Centaur Charger 12/30(3) – CCH012030000-Powerland

    Powerland Victron Energy Centaur Charger 12/30(3) – CCH012030000

    The Centaur range of battery chargers features auto-ranging input covering 90-265VAC 50/60Hz input meaning they can be used anywhere in the world. Crucially, and unlike many other products that state universal input, the Centaur range will maintain full output power within the entire specified range. Other features include fully automatic three stage charge characteristic that ensures batteries are fully charged every time and three isolated charge outputs for multi battery configurations to suit the majority of typical installations. The range spans 12V and 24V models from 16A through to 100A.   Features Quality without compromise Aluminium epoxy powder coated cases with drip shield and stainless steel fixings withstand the rigors of an adverse environment: heat, humidity and salt air. Circuit boards are protected with an acrylic coating for maximum corrosion resistance. Temperature sensors ensure that power components will always operate within specified limits, if needed by automatic reduction of output current under extreme environmental conditions. Universal 90-265V AC input voltage range and also suitable for DC supply (AC-DC and DC-DC operation) All models will operate without any adjustment needed over a 90 to 265 Volt input voltage range, whether 50 Hz or 60 Hz. The chargers also accept a 90-400 V DC supply. Three outputs that each can supply the full output current Three isolated outputs to simultaneously charge 3 battery banks. Each output is capable to supply the full rated current. Three-stage charging, with temperature compensation The Centaur charges at bulk rate until the output has reduced to 70% of the rated Amps, at which a 4 hour timer begins. After the timed period the charger switches to float rate. An internal temperature sensor is used to compensate the charge voltage with – 2 mV/ºC (– 1 mV/ºF) per cell. A DIP switch is available to select the optimum charge/float voltages for Flooded Lead-acid, Gel or AGM batteries. CLICK HERE FOR SPEC SHEET Brand Victron Energy Manufacturer Part Number CCH012030000 Voltage 12 Charger Amps 30 Outputs 3 Recommended Battery Capacity 120 – 300Ah Battery Connection M6 Studs IP Rating IP20 Dimensions H355 x W215 x D110mm Weight (kg) 3.8 Warranty 5 Years

    £287.40 Exc. VAT

    £344.88 Inc. VAT

  • Victron Energy Centaur Charger 24/16(3) – CCH024016000-Powerland

    Powerland Victron Energy Centaur Charger 24/16(3) – CCH024016000

    The Centaur range of battery chargers features auto-ranging input covering 90-265VAC 50/60Hz input meaning they can be used anywhere in the world. Crucially, and unlike many other products that state universal input, the Centaur range will maintain full output power within the entire specified range. Other features include fully automatic three stage charge characteristic that ensures batteries are fully charged every time and three isolated charge outputs for multi battery configurations to suit the majority of typical installations. The range spans 12V and 24V models from 16A through to 100A.   Features Quality without compromise Aluminium epoxy powder coated cases with drip shield and stainless steel fixings withstand the rigors of an adverse environment: heat, humidity and salt air. Circuit boards are protected with an acrylic coating for maximum corrosion resistance. Temperature sensors ensure that power components will always operate within specified limits, if needed by automatic reduction of output current under extreme environmental conditions.   Universal 90-265V AC input voltage range and also suitable for DC supply (AC-DC and DC-DC operation) All models will operate without any adjustment needed over a 90 to 265 Volt input voltage range, whether 50 Hz or 60 Hz. The chargers also accept a 90-400 V DC supply.   Three outputs that each can supply the full output current Three isolated outputs to simultaneously charge 3 battery banks. Each output is capable to supply the full rated current.   Three-stage charging, with temperature compensation The Centaur charges at bulk rate until the output has reduced to 70% of the rated Amps, at which a 4 hour timer begins. After the timed period the charger switches to float rate. An internal temperature sensor is used to compensate the charge voltage with – 2 mV/ºC (– 1 mV/ºF) per cell. A DIP switch is available to select the optimum charge/float voltages for Flooded Lead-acid, Gel or AGM batteries. CLICK HERE FOR SPEC SHEET Brand Victron Energy Manufacturer Part Number CCH012100000 Voltage 12 Charger Amps 16 Outputs 3 Recommended Battery Capacity 45 – 150Ah Battery Connection M6 Studs IP Rating IP20 Dimensions H355 x W215 x D110mm Weight (kg) 3.8 Warranty 5 Years

    £318.00 Exc. VAT

    £381.60 Inc. VAT

  • Victron Energy Centaur Charger 12/40(3) – CCH012040000-Powerland

    Powerland Victron Energy Centaur Charger 12/40(3) – CCH012040000

    The Centaur range of battery chargers features auto-ranging input covering 90-265VAC 50/60Hz input meaning they can be used anywhere in the world. Crucially, and unlike many other products that state universal input, the Centaur range will maintain full output power within the entire specified range. Other features include fully automatic three stage charge characteristic that ensures batteries are fully charged every time and three isolated charge outputs for multi battery configurations to suit the majority of typical installations. The range spans 12V and 24V models from 16A through to 100A.   Features Quality without compromise Aluminium epoxy powder coated cases with drip shield and stainless steel fixings withstand the rigors of an adverse environment: heat, humidity and salt air. Circuit boards are protected with an acrylic coating for maximum corrosion resistance. Temperature sensors ensure that power components will always operate within specified limits, if needed by automatic reduction of output current under extreme environmental conditions.   Universal 90-265V AC input voltage range and also suitable for DC supply (AC-DC and DC-DC operation) All models will operate without any adjustment needed over a 90 to 265 Volt input voltage range, whether 50 Hz or 60 Hz. The chargers also accept a 90-400 V DC supply.   Three outputs that each can supply the full output current Three isolated outputs to simultaneously charge 3 battery banks. Each output is capable to supply the full rated current.   Three-stage charging, with temperature compensation The Centaur charges at bulk rate until the output has reduced to 70% of the rated Amps, at which a 4 hour timer begins. After the timed period the charger switches to float rate. An internal temperature sensor is used to compensate the charge voltage with – 2 mV/ºC (– 1 mV/ºF) per cell. A DIP switch is available to select the optimum charge/float voltages for Flooded Lead-acid, Gel or AGM batteries.   CLICK HERE FOR SPEC SHEET Brand Victron Energy Manufacturer Part Number CCH012040000 Voltage 12 Charger Amps 40 Recommended Battery Capacity 160 – 400Ah Battery Connection M8 Studs Outputs 3 IP Rating IP20 Dimensions H426 x W239 x D135mm Weight (kg) 5 Warranty 5 Years

    £352.70 Exc. VAT

    £423.24 Inc. VAT

  • Victron Energy Centaur Charger 12/50(3) – CCH012050000-Powerland

    Powerland Victron Energy Centaur Charger 12/50(3) – CCH012050000

    The Centaur range of battery chargers features auto-ranging input covering 90-265VAC 50/60Hz input meaning they can be used anywhere in the world. Crucially, and unlike many other products that state universal input, the Centaur range will maintain full output power within the entire specified range. Other features include fully automatic three stage charge characteristic that ensures batteries are fully charged every time and three isolated charge outputs for multi battery configurations to suit the majority of typical installations. The range spans 12V and 24V models from 16A through to 100A.   Features Quality without compromise Aluminium epoxy powder coated cases with drip shield and stainless steel fixings withstand the rigors of an adverse environment: heat, humidity and salt air. Circuit boards are protected with an acrylic coating for maximum corrosion resistance. Temperature sensors ensure that power components will always operate within specified limits, if needed by automatic reduction of output current under extreme environmental conditions. Universal 90-265V AC input voltage range and also suitable for DC supply (AC-DC and DC-DC operation) All models will operate without any adjustment needed over a 90 to 265 Volt input voltage range, whether 50 Hz or 60 Hz. The chargers also accept a 90-400 V DC supply. Three outputs that each can supply the full output current Three isolated outputs to simultaneously charge 3 battery banks. Each output is capable to supply the full rated current. Three-stage charging, with temperature compensation The Centaur charges at bulk rate until the output has reduced to 70% of the rated Amps, at which a 4 hour timer begins. After the timed period the charger switches to float rate. An internal temperature sensor is used to compensate the charge voltage with – 2 mV/ºC (– 1 mV/ºF) per cell. A DIP switch is available to select the optimum charge/float voltages for Flooded Lead-acid, Gel or AGM batteries. CLICK HERE FOR SPEC SHEET Brand Victron Energy Manufacturer Part Number CCH012050000 Voltage 12 Charger Amps 50 Outputs 3 Recommended Battery Capacity 200 – 500Ah Battery Connection M8 Studs IP Rating IP20 Dimensions H426 x W239 x D135mm Weight (kg) 5 Warranty 5 Years

    £366.60 Exc. VAT

    £439.92 Inc. VAT

  • Victron Energy Centaur Charger 12/60(3) – CCH012060000-Powerland

    Powerland Victron Energy Centaur Charger 12/60(3) – CCH012060000

    The Centaur range of battery chargers features auto-ranging input covering 90-265VAC 50/60Hz input meaning they can be used anywhere in the world. Crucially, and unlike many other products that state universal input, the Centaur range will maintain full output power within the entire specified range. Other features include fully automatic three stage charge characteristic that ensures batteries are fully charged every time and three isolated charge outputs for multi battery configurations to suit the majority of typical installations. The range spans 12V and 24V models from 16A through to 100A.   Features Quality without compromise Aluminium epoxy powder coated cases with drip shield and stainless steel fixings withstand the rigors of an adverse environment: heat, humidity and salt air. Circuit boards are protected with an acrylic coating for maximum corrosion resistance. Temperature sensors ensure that power components will always operate within specified limits, if needed by automatic reduction of output current under extreme environmental conditions.   Universal 90-265V AC input voltage range and also suitable for DC supply (AC-DC and DC-DC operation) All models will operate without any adjustment needed over a 90 to 265 Volt input voltage range, whether 50 Hz or 60 Hz. The chargers also accept a 90-400 V DC supply.   Three outputs that each can supply the full output current Three isolated outputs to simultaneously charge 3 battery banks. Each output is capable to supply the full rated current.   Three-stage charging, with temperature compensation The Centaur charges at bulk rate until the output has reduced to 70% of the rated Amps, at which a 4 hour timer begins. After the timed period the charger switches to float rate. An internal temperature sensor is used to compensate the charge voltage with – 2 mV/ºC (– 1 mV/ºF) per cell. A DIP switch is available to select the optimum charge/float voltages for Flooded Lead-acid, Gel or AGM batteries. CLICK HERE FOR SPEC SHEET Brand Victron Energy Manufacturer Part Number CCH012060000 Voltage 12 Charger Amps 60 Outputs 3 Recommended Battery Capacity 240 – 600Ah Battery Connection M8 Studs IP Rating IP20 Dimensions H426 x W239 x H135mm Weight (kg) 5 Warranty 5 Years

    £381.00 Exc. VAT

    £457.20 Inc. VAT

  • Victron Energy Centaur Charger 24/30(3) – CCH024030000-Powerland

    Powerland Victron Energy Centaur Charger 24/30(3) – CCH024030000

    The Centaur range of battery chargers features auto-ranging input covering 90-265VAC 50/60Hz input meaning they can be used anywhere in the world. Crucially, and unlike many other products that state universal input, the Centaur range will maintain full output power within the entire specified range. Other features include fully automatic three stage charge characteristic that ensures batteries are fully charged every time and three isolated charge outputs for multi battery configurations to suit the majority of typical installations. The range spans 12V and 24V models from 16A through to 100A.   Features Quality without compromise Aluminium epoxy powder coated cases with drip shield and stainless steel fixings withstand the rigors of an adverse environment: heat, humidity and salt air. Circuit boards are protected with an acrylic coating for maximum corrosion resistance. Temperature sensors ensure that power components will always operate within specified limits, if needed by automatic reduction of output current under extreme environmental conditions.   Universal 90-265V AC input voltage range and also suitable for DC supply (AC-DC and DC-DC operation) All models will operate without any adjustment needed over a 90 to 265 Volt input voltage range, whether 50 Hz or 60 Hz. The chargers also accept a 90-400 V DC supply.   Three outputs that each can supply the full output current Three isolated outputs to simultaneously charge 3 battery banks. Each output is capable to supply the full rated current.   Three-stage charging, with temperature compensation The Centaur charges at bulk rate until the output has reduced to 70% of the rated Amps, at which a 4 hour timer begins. After the timed period the charger switches to float rate. An internal temperature sensor is used to compensate the charge voltage with – 2 mV/ºC (– 1 mV/ºF) per cell. A DIP switch is available to select the optimum charge/float voltages for Flooded Lead-acid, Gel or AGM batteries.   CLICK HERE FOR SPEC SHEET Brand Victron Energy Manufacturer Part Number CCH024030000 Voltage 24 Charger Amps 30 Outputs 3 Recommended Battery Capacity 120 – 300Ah Battery Connection M8 Studs IP Rating IP20 Dimensions H426 x W239 x D135mm Weight (kg) 5 Warranty 5 Years

    £445.00 Exc. VAT

    £534.00 Inc. VAT

  • Victron Energy Centaur Charger 24/40(3) – CCH024040000-Powerland

    Powerland Victron Energy Centaur Charger 24/40(3) – CCH024040000

    The Centaur range of battery chargers features auto-ranging input covering 90-265VAC 50/60Hz input meaning they can be used anywhere in the world. Crucially, and unlike many other products that state universal input, the Centaur range will maintain full output power within the entire specified range. Other features include fully automatic three stage charge characteristic that ensures batteries are fully charged every time and three isolated charge outputs for multi battery configurations to suit the majority of typical installations. The range spans 12V and 24V models from 16A through to 100A.   Features Quality without compromise Aluminium epoxy powder coated cases with drip shield and stainless steel fixings withstand the rigors of an adverse environment: heat, humidity and salt air. Circuit boards are protected with an acrylic coating for maximum corrosion resistance. Temperature sensors ensure that power components will always operate within specified limits, if needed by automatic reduction of output current under extreme environmental conditions.   Universal 90-265V AC input voltage range and also suitable for DC supply (AC-DC and DC-DC operation) All models will operate without any adjustment needed over a 90 to 265 Volt input voltage range, whether 50 Hz or 60 Hz. The chargers also accept a 90-400 V DC supply.   Three outputs that each can supply the full output current Three isolated outputs to simultaneously charge 3 battery banks. Each output is capable to supply the full rated current.   Three-stage charging, with temperature compensation The Centaur charges at bulk rate until the output has reduced to 70% of the rated Amps, at which a 4 hour timer begins. After the timed period the charger switches to float rate. An internal temperature sensor is used to compensate the charge voltage with – 2 mV/ºC (– 1 mV/ºF) per cell. A DIP switch is available to select the optimum charge/float voltages for Flooded Lead-acid, Gel or AGM batteries. CLICK HERE FOR SPEC SHEET Brand Victron Energy Manufacturer Part Number CCH024040000 Voltage 24 Charger Amps 40 Outputs 3 Recommended Battery Capacity 160 – 400Ah Battery Connection M8 Studs IP Rating IP20 Dimensions H505 x W255 x x H130mm Weight (kg) 12 Warranty 5 Years

    £580.00 Exc. VAT

    £696.00 Inc. VAT

  • Victron Energy Centaur Charger 12/80(3) – CCH012080000-Powerland

    Powerland Victron Energy Centaur Charger 12/80(3) – CCH012080000

    The Centaur range of battery chargers features auto-ranging input covering 90-265VAC 50/60Hz input meaning they can be used anywhere in the world. Crucially, and unlike many other products that state universal input, the Centaur range will maintain full output power within the entire specified range. Other features include fully automatic three stage charge characteristic that ensures batteries are fully charged every time and three isolated charge outputs for multi battery configurations to suit the majority of typical installations. The range spans 12V and 24V models from 16A through to 100A.   Features Quality without compromise Aluminium epoxy powder coated cases with drip shield and stainless steel fixings withstand the rigors of an adverse environment: heat, humidity and salt air. Circuit boards are protected with an acrylic coating for maximum corrosion resistance. Temperature sensors ensure that power components will always operate within specified limits, if needed by automatic reduction of output current under extreme environmental conditions.   Universal 90-265V AC input voltage range and also suitable for DC supply (AC-DC and DC-DC operation) All models will operate without any adjustment needed over a 90 to 265 Volt input voltage range, whether 50 Hz or 60 Hz. The chargers also accept a 90-400 V DC supply.   Three outputs that each can supply the full output current Three isolated outputs to simultaneously charge 3 battery banks. Each output is capable to supply the full rated current.   Three-stage charging, with temperature compensation The Centaur charges at bulk rate until the output has reduced to 70% of the rated Amps, at which a 4 hour timer begins. After the timed period the charger switches to float rate. An internal temperature sensor is used to compensate the charge voltage with – 2 mV/ºC (– 1 mV/ºF) per cell. A DIP switch is available to select the optimum charge/float voltages for Flooded Lead-acid, Gel or AGM batteries. CLICK HERE FOR SPEC SHEET Brand Victron Energy Manufacturer Part Number CCH012080000 Voltage 12 Charger Amps 80 Outputs 3 Recommended Battery Capacity 320 – 800Ah Battery Connection M8 Studs IP Rating IP20 Dimensions H505 x W255 x x H130mm Weight (kg) 12 Warranty 5 Years

    £632.00 Exc. VAT

    £758.40 Inc. VAT

  • Victron Energy Centaur Charger 24/60(3) – CCH024060000-Powerland

    Powerland Victron Energy Centaur Charger 24/60(3) – CCH024060000

    The Centaur range of battery chargers features auto-ranging input covering 90-265VAC 50/60Hz input meaning they can be used anywhere in the world. Crucially, and unlike many other products that state universal input, the Centaur range will maintain full output power within the entire specified range. Other features include fully automatic three stage charge characteristic that ensures batteries are fully charged every time and three isolated charge outputs for multi battery configurations to suit the majority of typical installations. The range spans 12V and 24V models from 16A through to 100A.   Features Quality without compromise Aluminium epoxy powder coated cases with drip shield and stainless steel fixings withstand the rigors of an adverse environment: heat, humidity and salt air. Circuit boards are protected with an acrylic coating for maximum corrosion resistance. Temperature sensors ensure that power components will always operate within specified limits, if needed by automatic reduction of output current under extreme environmental conditions.   Universal 90-265V AC input voltage range and also suitable for DC supply (AC-DC and DC-DC operation) All models will operate without any adjustment needed over a 90 to 265 Volt input voltage range, whether 50 Hz or 60 Hz. The chargers also accept a 90-400 V DC supply.   Three outputs that each can supply the full output current Three isolated outputs to simultaneously charge 3 battery banks. Each output is capable to supply the full rated current.   Three-stage charging, with temperature compensation The Centaur charges at bulk rate until the output has reduced to 70% of the rated Amps, at which a 4 hour timer begins. After the timed period the charger switches to float rate. An internal temperature sensor is used to compensate the charge voltage with – 2 mV/ºC (– 1 mV/ºF) per cell. A DIP switch is available to select the optimum charge/float voltages for Flooded Lead-acid, Gel or AGM batteries. CLICK HERE FOR SPEC SHEET Brand Victron Energy Manufacturer Part Number CCH024060000 Voltage 24 Charger Amps 60 Outputs 3 Recommended Battery Capacity 240 – 600Ah Battery Connection M8 Studs IP Rating IP20 Dimensions H505 x W255 x x H130mm Weight (kg) 12 Warranty 5 Years

    £664.00 Exc. VAT

    £796.80 Inc. VAT

  • Victron Energy Centaur Charger 12/100(3) – CCH012100000-Powerland

    Powerland Victron Energy Centaur Charger 12/100(3) – CCH012100000

    The Centaur range of battery chargers features auto-ranging input covering 90-265VAC 50/60Hz input meaning they can be used anywhere in the world. Crucially, and unlike many other products that state universal input, the Centaur range will maintain full output power within the entire specified range. Other features include fully automatic three stage charge characteristic that ensures batteries are fully charged every time and three isolated charge outputs for multi battery configurations to suit the majority of typical installations. The range spans 12V and 24V models from 16A through to 100A.   Features Quality without compromise Aluminium epoxy powder coated cases with drip shield and stainless steel fixings withstand the rigors of an adverse environment: heat, humidity and salt air. Circuit boards are protected with an acrylic coating for maximum corrosion resistance. Temperature sensors ensure that power components will always operate within specified limits, if needed by automatic reduction of output current under extreme environmental conditions.   Universal 90-265V AC input voltage range and also suitable for DC supply (AC-DC and DC-DC operation) All models will operate without any adjustment needed over a 90 to 265 Volt input voltage range, whether 50 Hz or 60 Hz. The chargers also accept a 90-400 V DC supply.   Three outputs that each can supply the full output current Three isolated outputs to simultaneously charge 3 battery banks. Each output is capable to supply the full rated current.   Three-stage charging, with temperature compensation The Centaur charges at bulk rate until the output has reduced to 70% of the rated Amps, at which a 4 hour timer begins. After the timed period the charger switches to float rate. An internal temperature sensor is used to compensate the charge voltage with – 2 mV/ºC (– 1 mV/ºF) per cell. A DIP switch is available to select the optimum charge/float voltages for Flooded Lead-acid, Gel or AGM batteries.   CLICK HERE FOR SPEC SHEET Brand Victron Energy Manufacturer Part Number CCH012100000 Voltage 12 Charger Amps 100 Outputs 3 Recommended Battery Capacity 400 – 1000Ah Battery Connection M8 Studs IP Rating IP20 Dimensions H505 x W255 x x H130mm Weight (kg) 12 Warranty 5 Years

    £772.90 Exc. VAT

    £927.48 Inc. VAT

Forgot Password


Back to top